Description
Valve and thermocouple Operation Instructions
1). Fix the valve on a plate or board of your grill or fire pit by the head screw and flange.
2). Connect your inlet and outlet hose on inlet and outlet side. (faston it tightly enough in case of gas leakage)
3). Faston the thermocouple nut M8 on the valve end tightly (Check if your valve end thread if 8mm before you buy)
4). Connect thermocouple and end thread well
5). Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough.
6). Release your hand and it work properly If when you release hand, gas valve shut off again, Please check
une. If your thermocouple is always be heated on flame
b. If the thermocouple end is well connect with valve
c. If the inlet and outlet side well connect with hose you have
Conseils:
The regulator hose and corrugated hose should be well connected when using. Must obey above valve and thermocouple operation instructions then this system can be worked perfectly. ONLY SUITABLE FOR LOW PRESSURE SYSTEM Under 50000BTU.
Commentaires
Il n'y a pas encore de critiques.